563 research outputs found
A Study of a Mini-drift GEM Tracking Detector
A GEM tracking detector with an extended drift region has been studied as
part of an effort to develop new tracking detectors for future experiments at
RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB.
The detector consists of a triple GEM stack with a small drift region that was
operated in a mini TPC type configuration. Both the position and arrival time
of the charge deposited in the drift region were measured on the readout plane
which allowed the reconstruction of a short vector for the track traversing the
chamber. The resulting position and angle information from the vector could
then be used to improve the position resolution of the detector for larger
angle tracks, which deteriorates rapidly with increasing angle for conventional
GEM tracking detectors using only charge centroid information. Two types of
readout planes were studied. One was a COMPASS style readout plane with 400
micron pitch XY strips and the other consisted of 2x10mm2 chevron pads. The
detector was studied in test beams at Fermilab and CERN, along with additional
measurements in the lab, in order to determine its position and angular
resolution for incident track angles up to 45 degrees. Several algorithms were
studied for reconstructing the vector using the position and timing information
in order to optimize the position and angular resolution of the detector for
the different readout planes. Applications for large angle tracking detectors
at RHIC and EIC are also discussed.Comment: Submitted to the IEEE Transactions on Nuclear Scienc
Design, Construction, Operation and Performance of a Hadron Blind Detector for the PHENIX Experiment
A Hadron Blind Detector (HBD) has been developed, constructed and
successfully operated within the PHENIX detector at RHIC. The HBD is a
Cherenkov detector operated with pure CF4. It has a 50 cm long radiator
directly coupled in a window- less configuration to a readout element
consisting of a triple GEM stack, with a CsI photocathode evaporated on the top
surface of the top GEM and pad readout at the bottom of the stack. This paper
gives a comprehensive account of the construction, operation and in-beam
performance of the detector.Comment: 51 pages, 39 Figures, submitted to Nuclear Instruments and Method
Construction and Expected Performance of the Hadron Blind Detector for the PHENIX Experiment at RHIC
A new Hadron Blind Detector (HBD) for electron identification in high density
hadron environment has been installed in the PHENIX detector at RHIC in the
fall of 2006. The HBD will identify low momentum electron-positron pairs to
reduce the combinatorial background in the mass spectrum, mainly
in the low-mass region below 1 GeV/c. The HBD is a windowless
proximity-focusing Cherenkov detector with a radiator length of 50 cm, a CsI
photocathode and three layers of Gas Electron Multipliers (GEM). The HBD uses
pure CF as a radiator and a detector gas. Construction details and the
expected performance of the detector are described.Comment: QM2006 proceedings, 4 pages 3 figure
A Hadron Blind Detector for the PHENIX Experiment
A novel Hadron Blind Detector (HBD) has been developed for an upgrade of the
PHENIX experiment at RHIC. The HBD will allow a precise measurement of
electron-positron pairs from the decay of the light vector mesons and the
low-mass pair continuum in heavy-ion collisions. The detector consists of a 50
cm long radiator filled with pure CF4 and directly coupled in a windowless
configuration to a triple Gas Electron Multiplier (GEM) detector with a CsI
photocathode evaporated on the top face of the first GEM foil.Comment: 4 pages, 3 figures, Quark Matter 2005 conference proceeding
Transverse Spin at PHENIX: Results and Prospects
The Relativistic Heavy Ion Collider (RHIC), as the world's first and only
polarized proton collider, offers a unique environment in which to study the
spin structure of the proton. In order to study the proton's transverse spin
structure, the PHENIX experiment at RHIC took data with transversely polarized
beams in 2001-02 and 2005, and it has plans for further running with transverse
polarization in 2006 and beyond. Results from early running as well as
prospective measurements for the future will be discussed.Comment: 6 pages, 2 figures, presented at Transversity 2005, Como, Ital
Recommended from our members
Multiparticle azimuthal correlations for extracting event-by-event elliptic and triangular flow in Au + Au collisions at sNN =200 GeV
We present measurements of elliptic and triangular azimuthal anisotropy of charged particles detected at forward rapidity 1<|η|<3 in Au + Au collisions at sNN=200 GeV, as a function of centrality. The multiparticle cumulant technique is used to obtain the elliptic flow coefficients v2{2},v2{4},v2{6}, and v2{8}, and triangular flow coefficients v3{2} and v3{4}. Using the small-variance limit, we estimate the mean and variance of the event-by-event v2 distribution from v2{2} and v2{4}. In a complementary analysis, we also use a folding procedure to study the distributions of v2 and v3 directly, extracting both the mean and variance. Implications for initial geometrical fluctuations and their translation into the final-state momentum distributions are discussed
- …